Infrared Thermometer with 0.95 Emissivity -50°C to 500°C

Model No.: TM-3005B

The TM-3005B is a compact non-contact infrared thermometer with a -50°C to 500°C range, a 10:1 distance-to-spot ratio, fixed 0.95 emissivity, and a response time under 500 ms. It is positioned for fast surface checks in electrical, HVAC, and light industrial maintenance.

Request a QuoteAsk About SamplesWhatsApp Inquiry

Infrared Thermometer: Product Guide

Model No.: TM-3005B

The TM-3005B is a compact non-contact infrared thermometer with a -50°C to 500°C range, a 10:1 distance-to-spot ratio, fixed 0.95 emissivity, and a response time under 500 ms. It is positioned for fast surface checks in electrical, HVAC, and light industrial maintenance.

✨ Reference configuration

Measurement range -50°C to 500°C | fixed 0.95 emissivity | 10:1 distance-to-spot ratio | under-500 ms response | 10-second auto power-off.

Request a QuoteAsk About SamplesWhatsApp Inquiry

Infrared Thermometer: Key Features

Review the reference configuration below, then evaluate a sample for fit, controls, display visibility, and finish against your market requirements.

Fast Surface Checks with Under-500 ms Response

The reference response time is under 500 ms, which helps when checking multiple connection points, vents, or bearings in sequence. Let the meter settle to ambient temperature before a measurement series and allow for the target’s thermal mass.

Fixed 0.95 Emissivity for Common Materials

A fixed emissivity setting simplifies repeatable readings on many non-reflective surfaces such as painted metal, plastics, and masonry. For bare or reflective metals, confirm whether a different instrument or an emissivity adjustment is required.

Compact 104 g Body with 10-Second Auto Power-Off

The TM-3005B measures 147 × 91 × 40 mm and weighs 104 g. A 10-second auto power-off conserves battery life between spot checks; the meter uses two AAA batteries (not included).

Class II Laser and Backlit LCD

The 620–670 nm, under-1 mW Class II laser supports aiming, while the backlit LCD shows temperature and mode indicators. Data hold, °C/°F switching, low-battery indication, and a laser switch are included.

Key Functions

Key functions of the TM-3005B. Reference configuration; confirm final accessories against the approved sample.
Key functions of the TM-3005B. Reference configuration; confirm final accessories against the approved sample.

Infrared Thermometer Product Specifications

TM-3005B reference product specifications
Model number TM-3005B
Product name Infrared Thermometer
Measurement range -50°C to 500°C (-58°F to 932°F)
Accuracy (reference) ±2% of reading or ±2°C above 0°C; ±3°C from -30 to 0°C; ±5°C below -30°C
Repeatability ±1% of reading or ±1°C
Resolution 0.1°C
Distance-to-spot ratio 10:1
Response time Under 500 ms
Emissivity Fixed at 0.95
Laser 620–670 nm, under 1 mW, Class II
Display LCD with backlight
Functions Data hold, °C/°F, laser switch, low-battery indication
Auto power-off 10 seconds
Working environment 0°C to 40°C, 10%–85% RH
Storage temperature -20°C to 70°C
Power source AAA × 2 (not included)
Product weight 104 g
Product dimensions 147 × 91 × 40 mm
Packing 50.1 × 43.5 × 39.3 cm / 84 pcs; G.W. 11.93 kg; N.W. 12.63 kg
Customization Logo, color, packaging, manual, and selected configuration, subject to confirmation

Reference values come from the supplied product catalogue. Confirm the final specifications, accessories, and packaging against the quotation and approved sample.

Compare TM-3005B and TM-2102A Infrared Thermometers

Reference configurations at a glance
Feature TM-3005B TM-2102A
Measurement range -50°C to 500°C -50°C to 500°C
Distance-to-spot ratio 10:1 10:1
Reference accuracy ±2% or ±2°C; ±3°C; ±5°C ±4°C / ±3°C / ±1.5°C or ±1.5% / ±2%
Auto power-off 10 seconds 1 minute
Power source AAA × 2 AAA × 2
Product weight 104 g 124 g

Both models share a Class II laser, 10:1 optics, and a -50°C to 500°C range. The TM-3005B adds fixed 0.95 emissivity and a faster response in a lighter body; the TM-2102A adds a built-in torch and a longer auto-off window.

Choose the model that matches your measurement task, display preference, and packing requirements. A single specification does not establish overall performance in every application.

Private Label Infrared Thermometer and OEM/ODM Options

A coordinated product presentation needs clear instructions, consistent branding, and an agreed configuration. Discuss the following requirements with Holly Sourcing:

  • Branding: Share logo artwork and preferred placement on the infrared thermometer.
  • Appearance: Discuss housing colors, button colors, and printed details.
  • Packaging: Supply color-box artwork, insert requirements, and market languages.
  • Manual: Confirm instructions and safety text for the selected configuration.
  • Sample approval: Review fit, controls, labels, packing list, and final specifications before bulk purchasing.

Explore the full Test & Measurement Instruments range, or compare TM-2102A and TM-1943E.

Infrared Thermometer Documentation and Quality Checks

Request the model-specific documentation, declarations, and test reports for your selected configuration and destination market. Catalogue images and reference values are not a substitute for the approved specification sheet.

Inspect the housing, display, buttons, sensor or probe, battery compartment, and labels on the sample. Check the measurement mode, units, backlight, auto power-off, and accessory fit against the manual. Review the complete packing list before approval.

💬 Tell us which details matter most to your customers, such as display size, controls, packaging, or branding, when requesting a sample.

Warnings & Precautions

⚠️ Read and follow the supplied user manual before use.

  • This is an industrial surface-temperature instrument, not a medical thermometer. Do not use it for body-temperature screening or diagnosis.
  • Do not point the Class II laser at eyes or at highly reflective surfaces.
  • Fixed 0.95 emissivity may not suit bare metals, foils, or low-emissivity coatings. Confirm the measurement method for those materials.
  • Verify readings with a contact probe where accuracy is critical, and follow your safe work procedure on energized equipment.
  • Follow the stated cleaning, storage, and battery instructions. Do not use a damaged unit, cable, or accessory.
  • Keep the device and accessories out of reach of children.

Individual results vary with the application, material, and measurement technique. This description does not establish suitability for a specific safety, medical, or compliance purpose.

Infrared Thermometer FAQs

What is the measurement range of the TM-3005B?

The reference configuration measures -50°C to 500°C. Accuracy is stated as ±2% of reading or ±2°C above 0°C, with wider tolerances below 0°C.

What emissivity does the TM-3005B use?

The reference configuration uses a fixed emissivity of 0.95, which suits many painted, plastic, and masonry surfaces. Confirm suitability for reflective or bare-metal targets.

How fast is the TM-3005B?

The reference response time is under 500 ms. The display updates according to the measurement conditions and target stability.

Does the TM-3005B have a torch?

No. The TM-3005B reference configuration includes a laser switch and backlight but not the built-in torch listed for the TM-2102A.

Are batteries included with the TM-3005B?

The reference configuration uses two AAA batteries and lists them as excluded. Confirm the packing list for your order.

What are the MOQ, price, and lead time?

These depend on quantity, configuration, customization, and delivery requirements. Share your project brief for an applicable quotation.

Can I order a private label version?

Logo, appearance, packaging, manual, and selected configuration options are available for discussion. Confirm feasibility, specifications, and artwork before ordering.

Can I request a sample before bulk purchasing?

Contact Holly Sourcing to discuss sample availability, sample cost, shipping, and customization requirements.

What documentation is available for my market?

Request the model-specific specification sheet, declarations, and test reports for your destination market. Availability varies by configuration.

Request a Infrared Thermometer Quote or Sample

📩 Planning a tool or instrument range? Share your destination market, sales channel, estimated quantity, logo and packaging requirements, selected configuration, documentation needs, and delivery timing.

Request a QuoteAsk About SamplesWhatsApp Inquiry

Holly Sourcing Limited
Email: hollywang@hollysourcing.com
WhatsApp: +86 135 1099 7405
Company contact details